Error message
8900 Axis %.1s: noml. speed > %d 1/min: field weakening inactive
Cause of error
- The field weakening is not activated (MP2160 = 0)
- The nominal speed was higher than the rotational speed possible without field weakening
Error correction
- Activate the field weakening (set MP2160 to be unequal to 0)