Error message
Program start undefined
Cause of error
- The first block in the part program is a block with automatic pole assumption (CC without coordinates, ISO: G29).
- After a program interruption you pressed GOTO to select a block with automatic pole assumption.
Error correction
- Automatic pole assumption must not be the first coordinate block.
- To return to the program, use a positioning block with all coordinates.