Error message

E01B CC%d SPLC program error ERR-ID=%d ObjId=%d Param=%d

Cause of error

- The SPLC program has found an illegal value in an API marker or in an API word in the ApiToSafety (symbolic memory interface of SPLC to the safety software SKERN).
The additional information provides exact information:
ERR-ID = Information
ObjId = Depends on the ERR-ID
Param = Depends on the ERR-ID
ERR_ID:
100: PP_AxGrpStateReq - Range violation SPLC-CC
ObjektID = Axis group
Parameter = Value of the required safety function
200: PP_AxGrpActivate - Illegal marker value
ObjektID = Axis group
Parameter = 1 - SPLC CC marker value illegal
= 2 - SPLC MC marker value illegal
300: PP_AxFeedEnable - Illegal marker value
ObjektID = Axis
Parameter = 1 - SPLC CC marker value illegal
= 2 - SPLC MC marker value illegal
400: PP_AxGrpStopReq - Range violation SPLC CC
ObjektID = Axis group
Parameter = Value of the required safety function
500: PP_AxGrpPB - Illegal marker value
ObjektID = Axis group
Parameter = 1 - SPLC CC marker value illegal
= 2 - SPLC MC marker value illegal
600: PP_GenFB_NCC - Illegal marker value SPLC CC
ObjektID = No meaning
Parameter = No meaning
700: PP_GenCVO - Illegal marker value
ObjektID = No meaning
Parameter = 1 - SPLC CC marker value illegal
= 2 - SPLC MC marker value illegal
800: PP_AxGrpPermitDrvOn - Illegal marker value
ObjektID = Axis group
Parameter = 1 - SPLC CC marker value illegal
= 2 - SPLC MC marker value illegal
900: PP_GenMKG - Illegal marker value SPLC CC
ObjektID = No meaning
Parameter = No meaning
1000: PP_GenTBRK - Illegal marker value SPLC CC
ObjektID = No meaning
Parameter = No meaning

Error correction

- To set API words, use only the definitions of the corresponding datum in "SPlcApiMarker.def"
- Check the range limits of the API word.
- Check the values assigned to the API marker.
- Inform your service agency.