Error message
CC: Guard doors are open
Cause of error
- One or more guide doors are open
The guard doors have to be closed in order to conduct the safety self-test or the brake test of an axis.
Further possible causes:
- Faulty wiring of guard doors
- Guard door contact is defective
Error correction
- Close the guard doors in order to conduct the safety self-test or the brake test
Further possible measures:
- Check the wiring of the guard door contacts
- Check the guard door contact
- Check the SPLC program
- Inform your service agency