Error message
PLANE fct.: TURN not allowed!
Cause of error
You tried to run the TURN positioning behavior with the PLANE function during active M128 or active FUNCTION TCPM.
Error correction
When M128 or FUNCTION TCPM is active, in the PLANE function you can only use the positioning behaviors MOVE or STAY.