Error message

E007 CC%d S input not equal 0

Cause of error

Error in dynamic test of the 2nd emergency-stop loop.
In the dynamic test, O V is expected at all door contacts and key-operated-switch inputs after no later than 1.5 min. If a voltage of 24 V is present here, this error message appears.

Error correction

- Inform your service agency
- Check the wiring
- Check the door contacts, key-operated switches