Error message
Q303 in meas. cycle undefined!
Cause of error
In one of the measuring cycles 410 to 418, you did not define the parameter Q303 (measured value transfer)(current value =
-1). For reasons of security, however, selection of the measured value transfer is required to write the results of measurement
in
a table (datum table or preset table).
Error correction
Change parameter Q303 (measured value transfer) in the measuring cycle that is causing the error:
- Q303=0: Write the measured values with respect to the active workpiece coordinate system into the active datum table (activate
in the program with Cycle 7!).
- Q303=1: Write the measured values with respect to the active machine-based coordinate system (REF values) into the preset
table (activate in the program with Cycle 247!).
- Q303=-1: Measured value transfer is undefined. This value is automatically generated by the TNC when you download a program
that was written on a TNC 4xx or with an old software level of the iTNC 530, or if during the cycle definition you skipped
the
prompt for the measured value transfer with the END key.