Error message

M91/M92 not permitted

Cause of error

- You tried to use M91 or M92 to move to a machine-based position while a tilted working plane and tool radius compensation were active.
- You tried to use M91 or M92 to move to a machine-based position while a tilted working plane and M112 were active.
- You programmed positioning blocks with M91 or M92 within a program while global program settings were active.
- You tried to filter a program that contains NC blocks with M91 or M92.

Error correction

- Use only linear interpolation without tool radius compensation to move to machine-based positions while a tilted working plane is active.
- While M112 is active, do not move to machine-based positions while a tilted working plane is active.
- Reset global program settings in order to be able to execute positioning blocks with M91 or M92.
- Programs to be filtered must not contain any NC blocks with fixed machine coordinates (M91/M92).