Error message
Enter Q247 greater than 5
Cause of error
In a measuring cycle, you entered in parameter Q247 an angular step smaller than 5 degrees.
Error correction
To ensure sufficient measuring accuracy, enter an angular step (Q247) greater than 5 degrees.