380022

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


PROFIBUS DP: configuration of DP master bus %1 has been changed

%1 = Number of the affected bus

The PROFIBUS configuration on the DP master was changed during operation, e.g. by downloading a new hardware configuration via Step7. Since it is possible that the cycle data have changed, operation cannot be continued and a warm start is required.

If the DP master functionality is within the PLC (as on the 840Di), the PLC will have been stopped for the download and alarm 2000 (PLC sign-of-life) output.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

NCK restart

If the error cannot be eliminated by this procedure, please make a note of the error text and contact the control system manufacturer.

Switch control OFF - ON.


1-2767


© Siemens AG 2005 All Rights Reserved