380020

Parameters:


Definitions:


PROFIBUS DP: bus %3 SDB1000 error %1 for SDB source %2

%1 = Cause of the error

%2 = SDB1000 source

%3 = Number of the affected bus

Error in SDB1000 for PROFIBUS DP configuration.

Error cause:

01    = SDB1000 does not exist in SDB1000 source.

02    = SDB1000 in SDB1000 source too large.

03    = SDB1000 in SDB1000 source cannot be activated.

SDB1000 source:

00    = Default SDB (selected by MD 11240 = 0 if no user SDB1000 is loaded on the control system)

01    = Standard SDB1 (selected by MD 11240 = 1)

02    = Standard SDB2 (selected by MD 11240 = 2)


Reactions:


Remedy:


Program Continuation:


100    = SDB1000 stored in battery-backed memory (SRAM)

101    = User SDB1000 stored in file system

102    = SDB1000 reloaded in SRAM on startup

Reaction: PROFIBUS DP is inactive or operating in accordance with default SDB1000.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

Check MD 11240.

If SDB1000 source = 100: Reload user SDB1000 in passive file system /_N_IBN_DIR/ _N_SDB1000_BIN.

If SDB1000 source = 101: Check backup batteries.

If SDB1000 source = 102: Follow the procedure described for troubleshooting alarm 380 001.

If alarm 380 021 is also signaled, please follow the instructions provided for this alarm.

If the error cannot be eliminated by this procedure, please make a note of the error text and contact the control system manufacturer.

Switch control OFF - ON.


1-2765


© Siemens AG 2005 All Rights Reserved