311710 |
Axis %1 drive %2 resolution SSI motor measuring system invalid |
|
Parameters: |
%1 = NC axis number %2 = Drive number |
|
Definitions: |
The configuration of the motor measuring system for an SSI encoder is incorrect: MD_5022 $MD_ENC_ABS_RESOL_MOTOR must not be 0. |
|
Reactions: |
- Mode group not ready. - Channel not ready. - NC Start disable in this channel. |
|
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. Set MD_5022 $MD_ENC_ABS_RESOL_MOTOR to correct value: Rotary encoder: Singleturn resolution (increments per revolution). Linear encoder: Resolution of an increment (in nanometers). |
|
Program Continuation: |
Switch control OFF - ON. |
© Siemens AG 2005 All Rights Reserved