Remedy:
Program Continuation:
Axis %1 drive %2 knee area and saturation area of valve characteristic overlap
%1 = NC axis number %2 = Drive number
The knee area and the saturation area of the valve characteristic overlap.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
The knee area and the saturation area overlap if:
Positive quadrant: (MD 5465 + MD 5466) > MD 5486 Negative quadrant: (MD 5468 + MD 5466) > MD 5488 Enter a valid combination in the above drive MD.
Clear alarm with the RESET key in all channels. Restart part program.
© Siemens AG 2005 All Rights Reserved