310775

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 knee area and saturation area of valve characteristic overlap

%1 = NC axis number %2 = Drive number

The knee area and the saturation area of the valve characteristic overlap.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

The knee area and the saturation area overlap if:

Positive quadrant: (MD 5465 + MD 5466) > MD 5486 Negative quadrant: (MD 5468 + MD 5466) > MD 5488 Enter a valid combination in the above drive MD.

Clear alarm with the RESET key in all channels. Restart part program.


1-2755