310755

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 area factor too high

%1 = NC axis number %2 = Drive number

The positive area factor in drive MD 5462 AREA_FACTOR_POS_OUTPUT is too high or the negative area factor in drive MD 5463 AREA_FACTOR_NEG_OUTPUT is too high.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Select a smaller value for the positive area factor in drive MD 5462 AREA_FACTOR_POS_OUTPUT or select a smaller value for the negative area factor in drive MD 5463 AREA_FACTOR_NEG_OUTPUT.

Clear alarm with the RESET key in all channels. Restart part program.


1-2741


© Siemens AG 2005 All Rights Reserved