Remedy:
Program Continuation:
Axis %1 drive %2 number of encoder marks of measuring system invalid
%1 = NC axis number %2 = Drive number
The number of encoder marks of the motor measuring system in the drive MD 5005: ENC_RESOL_MOTOR (number of encoder marks of the motor measuring system) is zero or greater than the maximum input limit.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Match the number of encoder marks of the motor measuring system in drive MD 5005: ENC_RESOL_MOTOR (number of encoder marks of the motor measuring system) to the encoder in use. (Default setting for motor measuring system: (Default setting for motor measuring system: 2048 incr./rev.).
Switch control OFF - ON.
© Siemens AG 2005 All Rights Reserved