Axis %1 drive %2 measuring circuit error of absolute track, code %3
%1 = NC axis number %2 = Drive number %3 = Fine error coding
Absolute encoder (EQN 1325) Monitoring of the encoder hardware and the EnDat interface
More accurate diagnostics via MD5023: $MD_ENC_ABS_DIAGNOSIS_MOTOR (diagnostics for absolute track on motor measuring system).
Bit nos. and their meaning:
Bit 0 Lighting failed
Bit 1 Signal amplitude too small
Bit 2 Code connection error
Bit 3 Overvoltage
Bit 4 Undervoltage
Bit 5 Overcurrent
Bit 6 Battery change necessary
Bit 7 CRC error (evaluate bit 13), note: see below
Bit 8 Encoder cannot be used, assignment of absolute track to incremental track not allowed
Bit 9 C/D track for ERN 1387 encoder incorrect or EQN encoder connected
Bit 10 Log cannot be aborted
Bit 11 SSI level detected in data cable
Bit 12 TIMEOUT while reading measured value
Bit 13 CRC error (evaluate bit 7), note: see below
Bit 14 (810D) Wrong IPU submodule for direct measuring system
Bit 15 Encoder defective
CRC error: CRC error bit 7 and bit 13, meaning:
Bit 7: 0, bit 13: 1 CRC error from SIDA-ASIC Bit 7:1, bit 13: 0 Control check byte error
Bit 7: 1, bit 13: 1 Error on correction of absolute track by incremental track Bits 12 and 15: Zero level monitoring SSI Bits 14 and 15: Idle level monitoring SSI
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Check encoders, encoder lines and connectors between drive motor and 611D module. Check for temporary interruptions (loose contact) caused, for example, by movements in trailing cable. If necessary, replace the motor cable.
Incorrect cable type
Controller hardware not suitable for EnDat interface (e.g. control module with EPROM) Switch control OFF - ON.