301717

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Axis %1 drive %2 SSI transmission timeout

%1 = NC axis number %2 = Drive number

The SSI transmission must be completed within an NC clock cycle. This is not possible with its current parameterization.

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Either increase the clock cycle length of the NC or increase the SSI transmission rate (MD_1030 $MD_ACTUAL_VALUE_CONFIG_DIRECT.Bits 14 and 15).

The following transmission rates are possible: 100 kHz, 500 kHz, 1 MHz and 2 MHz. Caution: It might be possible that the length of the encoder cable does not allow an increase in frequency!

Switch control OFF - ON.

1-2715

© Siemens AG 2005 All Rights Reserved