301717
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 SSI transmission timeout
%1 = NC axis number %2 = Drive number
The SSI transmission must be completed within an NC clock cycle. This is not possible with its current parameterization.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Either increase the clock cycle length of the NC or increase the SSI transmission rate (MD_1030 $MD_ACTUAL_VALUE_CONFIG_DIRECT.Bits 14 and 15).
The following transmission rates are possible: 100 kHz, 500 kHz, 1 MHz and 2 MHz. Caution: It might be possible that the length of the encoder cable does not allow an increase in frequency!
Switch control OFF - ON.
1-2715