301712

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 multiturn SSI motor measuring system invalid

%1 = NC axis number %2 = Drive number

The configuration of a linear SSI motor measuring system is incorrect: A linear measuring system cannot have any multiturn information.

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Set MD_1021 $MD_ENC_ABS_TURNS_MOTOR (resolution number revolution) to 0. Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-2710