Remedy:
Program Continuation:
Axis %1 drive %2 multiturn SSI motor measuring system invalid
%1 = NC axis number %2 = Drive number
The configuration of a linear SSI motor measuring system is incorrect: A linear measuring system cannot have any multiturn information.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Set MD_1021 $MD_ENC_ABS_TURNS_MOTOR (resolution number revolution) to 0. Switch control OFF - ON.