Axis %1 drive %2 actual value synchronisation not allowed

%1 = NC axis number %2 = Drive number

The actual value synchronization for drift/slippage in MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable) is deselected. This is only allowed with SBH/SG monitoring, since the absolute actual position is irrelevant for this type of monitoring. However, safe end position and/or cam monitoring is also selected.

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Deselect actual value synchronization for drift/slippage or the safe end position and/or safe cam monitoring in MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable).

Switch control OFF - ON.