301708
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 actual value synchronisation not allowed
%1 = NC axis number %2 = Drive number
The actual value synchronization for drift/slippage in MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable) is deselected. This is only allowed with SBH/SG monitoring, since the absolute actual position is irrelevant for this type of monitoring. However, safe end position and/or cam monitoring is also selected.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Deselect actual value synchronization for drift/slippage or the safe end position and/or safe cam monitoring in MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable).
Switch control OFF - ON.
1-2706
© Siemens AG 2005 All Rights Reserved