301707

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Axis %1 drive %2 parameterization of modulo value for safe cam (SN) invalid

%1 = NC axis number %2 = Drive number

The cam modulo range parameterized for a rotary axis via MD 1305: $MD_SAFE_MODULO_RANGE (actual value range for safe cam with rotary axes) violates the rule stating that only integral multiples of 360 degrees may be set.

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Change parameterization of the cam modulo range in MD 1305: $MD_SAFE_MODULO_RANGE (actual value range for safe cam with rotary axes).

Switch control OFF - ON.

1-2705

© Siemens AG 2005 All Rights Reserved