301707
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 parameterization of modulo value for safe cam (SN) invalid
%1 = NC axis number %2 = Drive number
The cam modulo range parameterized for a rotary axis via MD 1305: $MD_SAFE_MODULO_RANGE (actual value range for safe cam with rotary axes) violates the rule stating that only integral multiples of 360 degrees may be set.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Change parameterization of the cam modulo range in MD 1305: $MD_SAFE_MODULO_RANGE (actual value range for safe cam with rotary axes).
Switch control OFF - ON.
1-2705
© Siemens AG 2005 All Rights Reserved