301702
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 track inversion incorrect
%1 = NC axis number %2 = Drive number
With rotary spindles without EnDat interface operating with enhanced controller modules, the track inversion (MD_1011.0=1) must not be switched on. Otherwise this error is triggered.
Modify MD 1011: $MD_ACTUAL_VALUE_CONFIG (actual value sensing configuration IM)
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. With rotary spindles without EnDat interface operating with enhanced controller modules, the track inversion must be performed by soldering the A and B tracks differently: A <-> B and A* <-> B*
Switch control OFF - ON.
1-2700
© Siemens AG 2005 All Rights Reserved