300861

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Axis %1 drive %2 generator mode: minimum axis speed > max. motor speed

%1 = NC axis number %2 = Drive number

The value in MD1635: $MD_GEN_AXIS_MIN_SPEED $MD_GEN_AXIS_MIN_SPEED (minimum generator axis speed) is greater than the value in MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).

-    Interface signals are set.

-    Alarm display.

Please inform the authorized personnel/service department.

Modify MD 1635: $MD_GEN_AXIS_MIN_SPEED generator axis) or

Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).

Alarm display showing cause of alarm disappears. No further operator action necessary.

1-2679

© Siemens AG 2005 All Rights Reserved