300860 |
Axis %1 drive %2 generator mode: emergency retraction speed > max. motor speed |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
The value entered for the emergency retraction speed in MD1639: $MD_RETRACT_SPEED (emergency retraction speed) is greater than MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed). |
Reactions: |
- Interface signals are set. - Alarm display. |
Remedy: |
Please inform the authorized personnel/service department. Modify MD 1639: $MD_RETRACT_SPEED (emergency retraction speed) or Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed). |
Program Continuation: |
Alarm display showing cause of alarm disappears. No further operator action necessary. |
© Siemens AG 2005 All Rights Reserved