300858

Axis %1 drive %2 generator mode: response voltage > switch-off threshold

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

The sum of the values in MD1631: $MD LINK VOLTAGE GEN ON (response voltage for generator axis) + MD1632: $MD LINK VOLTAGE GEN HYST (voltage range for generator control) is greater than MD1633: $MD_LINK_VOLTAGE_GEN_OFF (deactivation threshold for generator axis).

Reactions:

-    Interface signals are set.

-    Alarm display.

Remedy:

Please inform the authorized personnel/service department.

Modify drive machine data

Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or

Modify MD 1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) or

Modify MD 1633: $MD_LINK_VOLTAGE_GEN_OFF (voltage range for generator control) or

Program Continuation:

Alarm display showing cause of alarm disappears. No further operator action necessary.