300858 |
Axis %1 drive %2 generator mode: response voltage > switch-off threshold |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
The sum of the values in MD1631: $MD LINK VOLTAGE GEN ON (response voltage for generator axis) + MD1632: $MD LINK VOLTAGE GEN HYST (voltage range for generator control) is greater than MD1633: $MD_LINK_VOLTAGE_GEN_OFF (deactivation threshold for generator axis). |
Reactions: |
- Interface signals are set. - Alarm display. |
Remedy: |
Please inform the authorized personnel/service department. Modify drive machine data Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or Modify MD 1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) or Modify MD 1633: $MD_LINK_VOLTAGE_GEN_OFF (voltage range for generator control) or |
Program Continuation: |
Alarm display showing cause of alarm disappears. No further operator action necessary. |
© Siemens AG 2005 All Rights Reserved