300850
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 parameterization error in speed control adaption
%1 = NC axis number %2 = Drive number
The upper adaptation speed MD 1412: $MD_SPEEDCTRL_ADAPTSPEED_2 (upper adaptation speed) is less than the lower adaptation speed MD 1411: $MD_SPEEDCTRL_ADAPTSPEED_1 (lower adaptation speed).
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Modify MD 1412: $MD_SPEEDCTRL_ADAPTSPEED_2 (upper adaptation speed) and MD 1411: $MD_SPEEDCTRL_ADAPTSPEED_1 (lower adaptation speed).
Alarm display showing cause of alarm disappears. No further operator action necessary.
1-2673
© Siemens AG 2005 All Rights Reserved