300850

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Axis %1 drive %2 parameterization error in speed control adaption

%1 = NC axis number %2 = Drive number

The upper adaptation speed MD 1412: $MD_SPEEDCTRL_ADAPTSPEED_2 (upper adaptation speed) is less than the lower adaptation speed MD 1411: $MD_SPEEDCTRL_ADAPTSPEED_1 (lower adaptation speed).

-    Interface signals are set.

-    Alarm display.

Please inform the authorized personnel/service department. Modify MD 1412: $MD_SPEEDCTRL_ADAPTSPEED_2 (upper adaptation speed) and MD 1411: $MD_SPEEDCTRL_ADAPTSPEED_1 (lower adaptation speed).

Alarm display showing cause of alarm disappears. No further operator action necessary.

1-2673