300786

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 field weakening speed invalid

%1 = NC axis number %2 = Drive number

The value in MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weakening) is less than or equal to zero.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department.

For standard motors: Reset the drive (delete the bootfile) and repeat the startup.

For third-party motors: Check and, if necessary, refer to the motor data sheet to correct MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weakening). Clear alarm with the RESET key in all channels. Restart part program.


1-2667


© Siemens AG 2005 All Rights Reserved