300773 |
Axis %1 drive %2 asynchronous mode: feedforward control structure not possible |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
In asynchronous mode (select by MD 1465 < MD 1146) a feedforward control structure (MD 1004, bit 0 = 1) is not possible. Modify MD 1465: $MD_SWITCH_SPEED_MSD_AM (switchover speed MSD/AM) Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed) Modify MD 1004: $MD_CTRL_CONFIG (configuration structure) The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready). |
Reactions: |
- NC not ready. - The NC switches to follow-up mode. - Channel not ready. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. - Channel not ready. Please inform the authorized personnel/service department. Rectify the error in the entry for the feedforward control structure MD 1004 or by deselecting the asynchronous mode MD 1465 > MD 1146. Modify MD 1004: $MD_CTRL_CONFIG (configuration structure) Modify MD 1465: $MD_SWITCH_SPEED_MSD_AM (switchover speed MSD/AM) Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed) |
Program Continuation: |
Clear alarm with the RESET key in all channels. Restart part program. |
© Siemens AG 2005 All Rights Reserved