300770

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 format error

%1 = NC axis number %2 = Drive number

The calculated filter coefficients of a bandstop filter are beyond the range of the internal format.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Change the filter setting. The Hotline provides support for accurate troubleshooting. Call the SIEMENS AG, SIMODRIVE Hotline.

Clear alarm with the RESET key in all channels. Restart part program.


1-2651


© Siemens AG 2005 All Rights Reserved