300768

Parameters:

Definitions:

Axis %1 drive %2 numerator bandwidth > double blocking frequency

%1 = NC axis number %2 = Drive number

The bandwidth numerator of a current or speed setpoint filter is greater than twice the blocking frequency.

This error message is only issued for the general bandstop filter if:

Speed setpoint filter 1:

MD 1516 > 0.0 or MD 1520 <> 100.0 Speed setpoint filter 2:

MD 1519 > 0.0 or MD 1521 <> 100.0 Current setpoint filter 1:

MD 1212 > 0.0 Current setpoint filter 2:

MD 1215 > 0.0 Current setpoint filter 3:

MD 1218 > 0.0 Current setpoint filter 4:

MD 1221 > 0.0

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

Reactions:

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Remedy:

Please inform the authorized personnel/service department.

The bandwidth numerator must be less than twice the blocking frequency.

Current setpoint filter 1:

MD 1212 <= 2 * MD 1210 Current setpoint filter 2:

MD 1215 <= 2 * MD 1213 Current setpoint filter 3:

MD 1218 <= 2 * MD 1216 Current setpoint filter 4:

MD 1221 <= 2 * MD 1219 Speed setpoint filter 1:

MD 1516 <= 2 * MD 1514 Speed setpoint filter 2:

MD 1519 <= 2 * MD 1517

Modify MD 1212: $MD_CURRENT_FILTER_1_BW_NUM (numerator bandwidth current setpoint filter 1)

Modify MD 1210: $MD_CURRENT_FILTER_1_SUPPR_FREQ (suppression frequency current setpoint filter 1)

Modify MD 1215: $MD_CURRENT_FILTER_2_BW_NUM (numerator bandwidth current setpoint filter 2)

1-2647