300765 |
Axis %1 drive %2 measurement of DC link voltage not possible |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
If the fixed voltage MD 1161: $MD_FIXED_LINK_VOLTAGE(DC link fixed voltage) = 0, no DC link measurement is possible because the hardware version is wrong. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready). |
Reactions: |
- NC not ready. - The NC switches to follow-up mode. - Channel not ready. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. - Channel not ready. Please inform the authorized personnel/service department. Enter a value greater than zero in the machine data MD 1161: $MD_FIXED_LINK_VOLTAGE (DC link fixed voltage), or order a new hardware version of the control module. |
Program Continuation: |
Clear alarm with the RESET key in all channels. Restart part program. |
© Siemens AG 2005 All Rights Reserved