300763

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 emergency retraction mode/generator mode invalid

%1 = NC axis number %2 = Drive number

Value specified by the NC via a G command must be in the range 0 to 7.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Check parameterization (G command in the NC).

Clear alarm with the RESET key in all channels. Restart part program.


© Siemens AG 2005 All Rights Reserved


1-2642