300761 |
Axis %1 drive %2 generator mode: minimum axis speed > max. motor speed |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
The value in MD1635: $MD_GEN_AXIS_MIN_SPEED $MD_GEN_AXIS_MIN_SPEED (minimum generator axis speed) is greater than the value in MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed). |
Reactions: |
- NC not ready. - The NC switches to follow-up mode. - Channel not ready. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. - Channel not ready. Please inform the authorized personnel/service department. Modify drive machine data Modify MD 1635: $MD_GEN_AXIS_MIN_SPEED generator axis) or Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed). |
Program Continuation: |
Clear alarm with the RESET key in all channels. Restart part program. |
© Siemens AG 2005 All Rights Reserved