300761

Axis %1 drive %2 generator mode: minimum axis speed > max. motor speed

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

The value in MD1635: $MD_GEN_AXIS_MIN_SPEED $MD_GEN_AXIS_MIN_SPEED (minimum generator axis speed) is greater than the value in MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).

Reactions:

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department.

Modify drive machine data

Modify MD 1635: $MD_GEN_AXIS_MIN_SPEED generator axis) or

Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).

Program Continuation:

Clear alarm with the RESET key in all channels. Restart part program.

© Siemens AG 2005 All Rights Reserved