Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 generator mode: response voltage > switch-off threshold
%1 = NC axis number %2 = Drive number
The sum of the values in MD1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) + MD1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) is greater than MD1633: $MD_LINK_VOLTAGE_GEN_OFF (deactivation threshold for generator axis).
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Please inform the authorized personnel/service department.
Modify drive machine data
Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or
Modify MD 1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) or
Modify MD 1633: $MD_LINK_VOLTAGE_GEN_OFF (voltage range for generator control) or
Clear alarm with the RESET key in all channels. Restart part program.