300757 |
Axis %1 drive %2 adaption factor of torque limit invalid |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
The torque adaptation factor MD 1191: $MD_TORQUE_LIMIT_ADAPT_SERVO (adaptation of servo limit torque) exceeds the format limit. |
Reactions: |
- NC not ready. - The NC switches to follow-up mode. - Channel not ready. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. - Channel not ready. Please inform the authorized personnel/service department. For standard motors: Reset the drive (delete the bootfile) and repeat the startup. For third-party motors: Check and, if necessary, correct the torque adaptation factor MD 1191: $MD_TORQUE_LIMIT_ADAPT_SERVO (adaptation of servo limit torque). |
Program Continuation: |
Clear alarm with the RESET key in all channels. Restart part program. |
© Siemens AG 2005 All Rights Reserved