300755

Axis %1 drive %2 voltage/frequency mode: motor is turning

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

Reactions:

The motor did not come to a standstill when the voltage/frequency mode was activated.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

Program Continuation:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Stop the motor before activating the voltage/frequency mode.

Clear alarm with the RESET key in all channels. Restart part program.

© Siemens AG 2005 All Rights Reserved

1-2634