300754

Axis %1 drive %2 signal number of var. signaling function invalid

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

The signal number for the output of the corresponding signaling function is not permissible. The signal number range is between 0 and 25.

Reactions:

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Enter the correct signal number.

Program Continuation:

Clear alarm with the RESET key in all channels. Restart part program.

1-2633