300742

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 voltage/frequency mode: converter frequency invalid

%1 = NC axis number %2 = Drive number

Only converter frequencies (MD 1100: $MD_PWM_FREQUENCY (pulse width modulation frequency)) of 4 kHz or 8 kHz are permissible in V/f mode (selected via MD 1014: $MD_UF_MODE_ENABLE).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Check and, if necessary, correct the torque adaptation factor MD 1100: $MD_PWM_FREQUENCY (pulse width modulation frequency) or remedy the problem by deselecting V/f mode MD 1014: $MD_UF_MODE_ENABLE.

Switch control OFF - ON.


1-2621


© Siemens AG 2005 All Rights Reserved