300738

Parameters:

Definitions:

Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 module number for measuring system not possible

%1 = NC axis number %2 = Drive number

The NC has assigned the direct measuring system to an axis which doesn't have a motor measuring system. This error can only occur with the 810D!

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Check the configuration of the direct measuring system. See NC-MD 30220: $MA_ENC_MODULE_NR and NC-MD 30230: $MA_ENC_INPUT_NR.

Switch control OFF - ON.


1-2617