300723
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 STS configuration of axes differ
%1 = NC axis number %2 = Drive number
The configuration of the control block MD 1003: $MD_STS_CONFIG (STS configuration) must be identical for both axes on 2-axis modules.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check drive MD 1003: $MD_STS_CONFIG (STS configuration) and set the bits for the two axes of the module so that they are the same. (Do not change the default setting - this corresponds to the optimum configuration).
Switch control OFF - ON.
1-2602