300722

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 zero-load motor current greater than rated current of power section

%1 = NC axis number %2 = Drive number

On the basis of its no-load current (MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current), the connected motor is too large for the power section in use (continuous thermal current MD 1108: $MD_INVERTER_MAX_THERMAL_CORR (current limit for power section).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department.

1.    Reset the drive (delete the bootfile) and repeat the startup.

2.    Check the configuration and install a suitable power section for the motor. Repeat the startup.

Switch control OFF - ON.


1-2601