300721 |
Axis %1 drive %2 zero-load current greater than rated motor current |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
The no-load current of the motor (MD 1136: $MD_MOTOR_NOLOAD_CURRENT) has been set at a greater value than the rated current of the motor (MD 1103: $MD_MOTOR_NOMINAL_CURRENT). |
Reactions: |
- NC not ready. - The NC switches to follow-up mode. - Channel not ready. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. Please inform the authorized personnel/service department. For standard motors: |
Program Continuation: |
Reset the drive (delete the bootfile) and repeat the startup. For third-party motors: Check and, if necessary, refer to the motor data sheet to correct machine data MD 1103: $MD MOTOR NOMINAL CURRENT (rated motor current) and MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current). Switch control OFF - ON. |
© Siemens AG 2005 All Rights Reserved
1-2600