300720

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 maximum motor speed invalid

%1 = NC axis number %2 = Drive number

Because of the high maximum motor speed in the drive MD 1401: $MD_MOTOR_MAX_SPEED and the speed controller cycle in MD 1001: $MD_SPEEDCTRL_CYCLE_TIME sufficiently high speeds can occur to cause a format overflow. Example: A motor speed of 480,000 rpm can still be processed without error at a speed controller cycle time of 125 ps.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Reduce the maximum motor speed MD 1401: $MD_MOTOR_MAX_SPEED (speed for the maximum useful motor speed) or set a smaller speed controller cycle in MD 1001: $MD_SPEEDCTRL_CYCLE_TIME (speed controller cycle).

Switch control OFF - ON.


1-2599