300717

Axis %1 drive %2 motor moment of inertia less than or equal to zero

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

The value in MD 1117: $MD_MOTOR_INERTIA (motor moment of inertia) is less than or equal to zero.

Reactions:

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department.

For standard motors: Reset the drive (delete the bootfile) and repeat the startup. For

MSD, configure "1st motor" first.

For third-party motors: Enter a valid value in drive MD 1117: $MD_MOTOR_INERTIA (motor moment of inertia).

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved

1-2596