300716

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 torque constant less than or equal to zero

%1 = NC axis number %2 = Drive number

1.    The value in drive MD 1113: $MD_TORQUE_CURRENT_RATIO (torque constant) is less than or equal to zero.

2.    The ratio of MD1113: $MD_TORQUE_CURRENT_RATIO (torque constant) / MD1112: $MD_NUM_POLE_PAIRS (motor pole pairs) is greater than 70.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department.

For standard motors: Reset the drive (delete the bootfile) and repeat the startup.

For third-party motors: Enter a valid value in drive MD 1113:

$MD_TORQUE_CURRENT_RATIO (torque constant), or check and, if necessary, correct the ratio of MD1113: $MD_TORQUE_CURRENT_RATIO (torque constant) / MD1112: $MD_NUM_POLE_PAIRS (motor pole pairs).

Switch control OFF - ON.


1-2595


© Siemens AG 2005 All Rights Reserved