300713

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 lead time for position controller invalid

%1 = NC axis number %2 = Drive number

The derivative-action time describes the point in time the setpoints are taken over in the drive. The derivative-action defined by the NC must be smaller than the position controller cycle. The derivative-action time must be an integer multiple of the speed controller cycle.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Modify MD 10082: $MN_CTROUT_LEAD_TIME (derivative-action time).

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-2592