300707

Axis %1 drive %2 basic cycle times of axes differ

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

In a 2-axis module, the basic drive cycle for the two axes is not the same. This alarm can only occur with OEM users who have the 611D drive without the standard NCK interface. This makes it possible for axially different basic drive cycles to be transferred to the 611D modules.

Reactions:

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Set the same basic drive cycle for both axes.

Program Continuation:

Switch control OFF - ON.