300704

Parameters:

Definitions:

Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 speed controller cycle time invalid

%1 = NC axis number %2 = Drive number

In the drive MD 1001: $MD_SPEEDCTRL_CYCLE_TIME.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. The following values are permissible:

611D control module Speed controller cycle Standard control as 1-axis: >= 125 ps Standard control as 2-axis: >= 500 ps Performance 1-axis: >= 62.5 ps (MSD >= 125 ps) Performance 2-axis: >= 125 ps 810D: >= 312.5 ps MCU: >= 125 ps

Performance 2, 1-axis: >= 31.25 ps Performance 2, 2-axis: >= 62.5 ps Switch control OFF - ON.


1-2583


© Siemens AG 2005 All Rights Reserved