300612

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 illegal current during rotor position identification

%1 = NC axis number %2 = Drive number

1.    With rotor position identification active, the current was >= 1.2 * 1.05 * INVERTER_MAX_CURRENT (MD 1107)

2.    With rotor position definition active, the current was >= MOTOR_MAX_CURRENT (MD 1104)

-    Mode group not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Check MD 1019 with rotor position identification active and, if necessary, reduce the setting.

Clear alarm with the RESET key in all channels of this mode group. Restart part program.


1-2577