300611 |
Axis %1 drive %2 generator mode: Motion at rotor position identification |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
During the measurement, the motor has turned by more than the permissible value entered in MD1020: $MD_MAX_TURN_ROTORPOS_IDENT (maximum rotation of the rotor position identification). The rotation can be caused by switching on a rotating motor or by the identification itself. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready). |
Reactions: |
- Mode group not ready. - The NC switches to follow-up mode. - Channel not ready. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. - Channel not ready. Please inform the authorized personnel/service department. If the rotation was caused by the identification itself, and if the error occurs repeatedly, then reduce MD1019: $MD_CURRENT_ROTORPOS_IDENT (rotor position identification current) or increase MD1020: $MD_MAX_TURN_ROTORPOS_IDENT (maximum rotation of the rotor position identification). Rotor position identification with inductance: stall the motor during the identification Rotor position identification with movement: check the factor load mass/load moment of inertia MD1076: $MD_FACTOR_MASS / $MD_FACTOR_INERTIA and increase if necessary. |
Program Continuation: |
Clear alarm with the RESET key in all channels of this mode group. Restart part program. |
© Siemens AG 2005 All Rights Reserved