300412

Error when storing a file (%1, %2)

Parameters:

%1 = Error code 1 %2 = Error code 2

Definitions:

An attempt to save a data block, i.e. the result of a measuring function, in the file system has failed.

Reactions:

-    Interface signals are set.

-    Alarm display.

Remedy:

Please inform the authorized personnel/service department. Create more space in the file system. It is normally sufficient to delete 2 NC programs or to free 4 - 8 Kbytes of memory.

If these remedies do not work, it will be necessary to increase the number of files per directory or the size of the file system itself. To do so, proceed as follows:

Save all data

Change settings of machine data

18280 $MM_NUM_FILES_PER_DIR

18320 $MM_NUM_FILES_IN_FILESYSTEM

18350 $MM_USER_FILE_MEM_MINIMUM and, if necessary, of

18270 $MM_NUM_SUBDIR_PER_DIR

18310 $MM_NUM_DIR_IN_FILESYSTEM

Power On

Reload saved data

Program Continuation:

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-2548